Check the manometer, the U-shaped gauge on the pipe. Unequal liquid levels mean the fan is pulling; liquid sitting level means it is not. Compare against the marked start-up reading, and retest the air every two years regardless.
More detail
The manometer is a wonderfully honest instrument: no batteries, no software, just liquid displaced by suction. At install the reading gets marked on the gauge or the pipe, and that mark is your baseline forever after. Level liquid is the unambiguous alarm, fan off or pipe blocked, check the breaker and the fan before calling. Drift matters too: suction falling steadily toward level suggests a tiring fan or a developing leak, while suction climbing well above the mark can mean the suction pit is pulling against a blockage. A monthly glance costs five seconds; put it on the furnace-filter rhythm. Remember the gauge's limit, though: it certifies airflow, not air quality. A system can pull beautifully while a new slab cut or a broken sump seal feeds gas in elsewhere, which is why the biennial $15 to $30 kit test stays on the calendar even for houses with healthy gauges. Odd readings are a quick service visit.